Described herein is a procedure for determining the path of the sun through the Florida sky relative to a solar collector array, a window, a skylight or an entire building - information needed by architects, engineers and others for shading and orientation calculations involved in active and passive building design. It can be used for positioning exterior shading devices for maximum benefit. This information can also be used to pinpoint solar collector shading problems.

Date Published

12-7-1983

Identifiers

1309

Subjects

Sun Position; Solar energy; Building; Architectural design; Solar collectors

Local Subjects

Solar Energy

Format

application/pdf

Collection

FSEC Energy Research Center® Collection

Share

COinS
 

Accessibility Statement

This item was created or digitized prior to April 24, 2027, or is a reproduction of legacy media created before that date. It is preserved in its original, unmodified state specifically for research, reference, or historical recordkeeping. In accordance with the ADA Title II Final Rule, the University Libraries provides accessible versions of archival materials upon request. To request an accommodation for this item, please submit an accessibility request form.