Keywords

stormwater, FDEP, exfiltration

Description

This report summarizes activities associated with a stormwater retrofitting project in Winter Park consisting of an exfiltration system. The project was funded, in part, by a TMDL Water Quality Restoration Grant. The report describes the contributing drainage area, pre-project stormwater pollutant loadings, post-project stormwater pollutant loadings, and summarizes the results of the monitoring program to document stormwater pollutant load reductions. Results of the monitoring program demonstrated that the exfiltration system reduced stormwater volume, TN loads, TP loads, and TSS loads by 83%. TN loadings were reduced from 105.5 kg/yr to 17.9 kg/yr; TP loadings were reduced from 27.1 kg/yr to 4.6 kg/yr, and TSS loadings were reduced from 3252 kg/yr to 553 kg/yr.

Contributors

Environmental Research and Design, Inc.

Date Created

7-1-2008

Type

Publication

Language

English

College

College of Engineering & Computer Science

Type

article

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.