Correlation of Human Metal Model and Transmission Line Pulsing Testing

Authors

    Authors

    S. Malobabic; J. A. Salcedo; A. W. Righter; J. J. Hajjar;J. J. Liou

    Comments

    Authors: contact us about adding a copy of your work at [email protected]

    Abbreviated Journal Title

    IEEE Electron Device Lett.

    Keywords

    Electrostatic discharge (ESD); human body model (HBM); human metal model; (HMM); transmission line pulsing (TLP); Engineering, Electrical & Electronic

    Abstract

    Passing voltage levels measured from the human metalmodel tester are correlated with the failure current levels obtained from the transmission line pulsing (TLP) tester for electrostatic discharge protection devices fabricated in 0.18- and 0.35-mu m MOS technologies. Various relevant TLP parameters, including the holding voltage and ON-state resistance, are accounted for in the improved correlation formula developed in this study.

    Journal Title

    Ieee Electron Device Letters

    Volume

    32

    Issue/Number

    9

    Publication Date

    1-1-2011

    Document Type

    Article

    Language

    English

    First Page

    1200

    Last Page

    1202

    WOS Identifier

    WOS:000294171600012

    ISSN

    0741-3106

    Share

    COinS
     

    Accessibility Statement

    This item was created or digitized prior to April 24, 2027, or is a reproduction of legacy media created before that date. It is preserved in its original, unmodified state specifically for research, reference, or historical recordkeeping. In accordance with the ADA Title II Final Rule, the University Libraries provides accessible versions of archival materials upon request. To request an accommodation for this item, please submit an accessibility request form.