Abstract
In this work a narrow linewidth (1 kHz) laser source is used to measure the free spectral range of a fiberized Fabry-Perot etalon with sub-Hz accuracy (10(-8)). A previously demonstrated technique based on the Pound-Drever-Hall error signal is improved in accuracy by the use of a narrow linewidth laser swept in frequency via an acousto-optic modulator, or single sideband generation. The sub-Hz (10(-8)) accuracy attained enables the characterization of both the long-term drift and the polarization dependence of the free spectral range of the fiberized etalon.
Journal Title
Optics Express
Volume
18
Issue/Number
11
Publication Date
1-1-2010
Document Type
Article
Language
English
First Page
11264
Last Page
11269
WOS Identifier
ISSN
1094-4087
Recommended Citation
Mandridis, Dimitrios; Ozdur, Ibrahim; Bagnell, Marcus; and Delfyett, Peter J., "Free spectral range measurement of a fiberized Fabry-Perot etalon with sub-Hz accuracy" (2010). Faculty Bibliography 2010s. 500.