Title
RELIABILITY, MINIMAL DETECTABLE CHANGE, AND NORMATIVE VALUES FOR TESTS OF UPPER EXTREMITY FUNCTION AND POWER
Abbreviated Journal Title
J. Strength Cond. Res.
Keywords
upper limb; functional tests; upper body strength and power; SHOULDER; REHABILITATION; DOMINANCE; SHOT; Sport Sciences
Abstract
Negrete, RJ, Hanney, WJ, Kolber, MJ, Davies, GJ, Ansley, MK, McBride, AB, and Overstreet, AL. Reliability, minimal detectable change, and normative values for tests of upper extremity function and power. J Strength Cond Res 24(12): 3318-3325, 2010-The purpose of this study was to examine the test-retest reliability, minimal detectable change (MDC), and determine normative values of 3 upper extremity (UE) tests of function and power. One hundred eighty participants, men (n = 69) and women (n = 111), were tested on 3 UE strength and power maneuvers in a multicenter study to determine baseline normative values. Forty-six subjects returned for a second day of testing within 5 days of the initial assessment for the reliability component of the investigation. Explosive power was assessed via a seated shot-put test for the dominant and nondominant arms. Relationships between the dominant and nondominant arms were also analyzed. A push-up and modified pull-up were performed to measure the amount of work performed in short (15-second) bursts of activity. The relationship between the push-up and modified pull-up was also determined. Analysis showed test-retest reliability for the modified pull-up, timed push-up, dominant single-arm seated shot-put tests, and nondominant single-arm seated shot-put tests to be intraclass correlation coefficient((3,1)) 0.958, 0.989, 0.988, and 0.971, respectively. The MDC for both the push-up and modified pull-up was 2 repetitions. The MDCs for the shot put with the dominant arm and the nondominant arm were 17 and 18 in., respectively. The result of this study indicates that these field tests possess excellent reliability. Normative values have been identified, which require further validation. These tests demonstrate a practical and effective method to measure upper extremity functional power.
Journal Title
Journal of Strength and Conditioning Research
Volume
24
Issue/Number
12
Publication Date
1-1-2010
Document Type
Article
Language
English
First Page
3318
Last Page
3325
WOS Identifier
ISSN
1064-8011
Recommended Citation
"RELIABILITY, MINIMAL DETECTABLE CHANGE, AND NORMATIVE VALUES FOR TESTS OF UPPER EXTREMITY FUNCTION AND POWER" (2010). Faculty Bibliography 2010s. 586.
https://stars.library.ucf.edu/facultybib2010/586
Comments
Authors: contact us about adding a copy of your work at STARS@ucf.edu