Prepare CIGSeS Cell Coupon and Test PV Modules at High Voltage, Final Report
Report Number
FSEC-CR-1936-12
Keywords
Photovoltaics; PV Thin-Films; Monitoring; CIGS thin film PV; High voltage testing; PV module reliability; Solar energy; Climate impact
Abstract
In order to transfer the CIGS thin film PV development from laboratory scale to pilot plan level, efforts are being made to develop a 2' X 2' CIGS thin film PV coupon. High voltage testing of PV module has been realized to be a very effective tool for reliability testing of PV modules in outdoor locations, especially in hot and humid climate. Efforts are being made to test the PV modules from various manufacturers in the hot and humid climate of Florida.
Date Published
10-11-2012
Identifiers
229
Subjects
Photovoltaic power systems; Thin film devices; High voltages; Climatic changes; Reliability
Local Subjects
Monitoring; Photovoltaics; PV Thin-Films
Collection
FSEC Energy Research Center® Collection
STARS Citation
Florida Solar Energy Center and Dhere, Neelkanth, "Prepare CIGSeS Cell Coupon and Test PV Modules at High Voltage, Final Report" (2012). FSEC Energy Research Center®. 229.
https://stars.library.ucf.edu/fsec/229
Accessibility Statement
This item was created or digitized prior to April 24, 2027, or is a reproduction of legacy media created before that date. It is preserved in its original, unmodified state specifically for research, reference, or historical recordkeeping. In accordance with the ADA Title II Final Rule, the University Libraries provides accessible versions of archival materials upon request. To request an accommodation for this item, please submit an accessibility request form.