Outdoor Monitoring and High Voltage Bias Testing of Thin-Film Photovoltaic Modules - Final Report
Report Number
FSEC-CR-1740-08
Keywords
PV Modules; PV Thin-Films; Monitoring; Thin-film photovoltaic modules; Solar irradiance; PV performance monitoring; Meteorological parameters; High voltage bias testing
Abstract
Thin film Photovoltaic (PV) modules from leading US PV manufacturers have been tested at Florida Solar Energy Center. The important PV module parameters namely array output voltage, current, and back-of-module temperatures along with meteorological parameters namely; solar irradiance, UV irradiance, relative humidity, ambient temperature, pressure and wind speed were monitored with an aim to study the correlation between the PV performance, solar irradiance and meteorological parameters.
Date Published
1-2-2008
Identifiers
428
Subjects
Photovoltaic power systems; Solar energy; Meteorological instruments; Electric measurements
Local Subjects
Monitoring; PV Modules; PV Thin-Films
Collection
FSEC Energy Research Center® Collection
STARS Citation
Florida Solar Energy Center and Dhere, Neelkanth, "Outdoor Monitoring and High Voltage Bias Testing of Thin-Film Photovoltaic Modules - Final Report" (2008). FSEC Energy Research Center®. 428.