Abstract
This report presents the results of cycle tests conducted on lead-acid batteries commonly used in stand-alone photovoltaic systems. The objectives of this work were to characterize battery performance under variable charge/discharge rates and variable regulation voltages, with the goal of developing meaningful recommendations for the PV system design community on the proper application and charge control requirements for these batteries.
Date Published
6-13-1997
Identifiers
749
Subjects
Storage batteries; Photovoltaic power systems; Electric batteries--Testing; Electric power systems--Design and construction
Local Subjects
Batteries; PV Systems
Type
Text; Document
Collection
FSEC Energy Research Center® Collection
STARS Citation
Florida Solar Energy Center and Dunlop, James, "Cycle Comparison of Lead-Acid Batteries Commonly Used in Small Stand-Alone Photovoltaic Systems" (1997). FSEC Energy Research Center®. 749.
https://stars.library.ucf.edu/fsec/749