Title
Performance Evaluation Of Divided Intake Ducts: Effect Of Area Ratio And Inlet Reynolds Number
Abstract
Investigations carried out on divided intake ducts with 22.5°/22.5° angle-of-turn to establish the effect of Reynolds number (Re = 6.27 · 104 to 1.88 · 105) and area ratios (2.0 to 4.0) using Computational Fluid Dynamics (CFD) code are reported. The core flow remains close to the convex wall at the duct outlet with magnitudes lower in the central region of the cross-section. It is found that static pressure recovery is around 65% and is independent of inlet Reynolds number for area ratio 2 duct (AR = 2). With increase in area ratio the static pressure recovery increases to 74% for AR = 2.5, 78% for AR = 3 and 80 % for AR = 4. The cross-velocity magnitudes at the exit for all the cases are found to be less than 5 % of the mean flow.
Publication Date
12-1-2003
Publication Title
International Journal of Fluid Mechanics Research
Volume
30
Issue
5
Number of Pages
525-541
Document Type
Article
Personal Identifier
scopus
DOI Link
https://doi.org/10.1615/InterJFluidMechRes.v30.i5.60
Copyright Status
Unknown
Socpus ID
8344225176 (Scopus)
Source API URL
https://api.elsevier.com/content/abstract/scopus_id/8344225176
STARS Citation
Bharani, Sanjeev; Singh, S. N.; and Seshadri, V., "Performance Evaluation Of Divided Intake Ducts: Effect Of Area Ratio And Inlet Reynolds Number" (2003). Scopus Export 2000s. 1354.
https://stars.library.ucf.edu/scopus2000/1354