Title

Large Signal Compensation Network Design For Vrm Transient Response Improvement

Abstract

Most of the compensation network designs in power supplies are based on the small signal model methods, which can not apply to the transient periods because it goes into the saturation region. The large signal response is determined by error amplifier dv/dt and main converter di/dt, a trade off between the stability and transient response. This paper presents one new control circuit to improve large signal transient response. Finally, experimental prototype was carried out in VRM with current injection converter to verify the theoretical analysis. © 2005 IEEE.

Publication Date

12-1-2005

Publication Title

IECON Proceedings (Industrial Electronics Conference)

Volume

2005

Number of Pages

1139-1143

Document Type

Article; Proceedings Paper

Personal Identifier

scopus

DOI Link

https://doi.org/10.1109/IECON.2005.1569065