Title
Alternated Duty Cycle Control Method For Half-Bridge Dc-Dc Converter
Abstract
A control method, namely, Alternated Duty Cycle (ADC) control, is presented in this paper. This method can achieve soft-switching for at least one switch of the two half-bridge switches. When soft-switching can be only achieved for one switch, ADC control alternates the soft-switching realization between the two switches so that each switch will be soft-switched during half of the time and hard-switched during the other half, keeping equal power losses distribution between the switches. Moreover, any asymmetry in the duty cycle will not cause asymmetric components stresses or transformer DC bias when ADC control is used. Theoretical analysis and implementation are presented along with experimental results.
Publication Date
11-29-2004
Publication Title
PESC Record - IEEE Annual Power Electronics Specialists Conference
Volume
1
Number of Pages
178-181
Document Type
Article; Proceedings Paper
Personal Identifier
scopus
DOI Link
https://doi.org/10.1109/PESC.2004.1355738
Copyright Status
Unknown
Socpus ID
8744317059 (Scopus)
Source API URL
https://api.elsevier.com/content/abstract/scopus_id/8744317059
STARS Citation
Abu-Qahouq, Jaber A.; Mao, Hong; and Batarseh, Issa, "Alternated Duty Cycle Control Method For Half-Bridge Dc-Dc Converter" (2004). Scopus Export 2000s. 4961.
https://stars.library.ucf.edu/scopus2000/4961