Abstract
This paper describes integrated membrane systems (IMS) performance at five sites, which employed chloramination, coagulation, sedimentation and filtration, GAC and/or size exclusion membrane filtration to enhance IMS productivity. Results indicate that effects of fouling are site specific, biological>organic>particle>precipitative fouling and all fouling mechanisms must be controlled for satisfactory IMS productivity for surface water sources.
Publication Date
1-1-2000
Publication Title
NACE - International Corrosion Conference Series
Volume
2000-March
Number of Pages
-
Document Type
Article; Proceedings Paper
Personal Identifier
scopus
Copyright Status
Unknown
Socpus ID
85046791499 (Scopus)
Source API URL
https://api.elsevier.com/content/abstract/scopus_id/85046791499
STARS Citation
Taylor, J. S. and Hong, S. K., "Integrated Membrane Systems" (2000). Scopus Export 2000s. 922.