Title
Correlation Of Human Metal Model And Transmission Line Pulsing Testing
Keywords
Electrostatic discharge (ESD); human body model (HBM); human metal model (HMM); transmission line pulsing (TLP)
Abstract
Passing voltage levels measured from the human metal model tester are correlated with the failure current levels obtained from the transmission line pulsing (TLP) tester for electrostatic discharge protection devices fabricated in 0.18-and 0.35-μm MOS technologies. Various relevant TLP parameters, including the holding voltage and on-state resistance, are accounted for in the improved correlation formula developed in this study. © 2011 IEEE.
Publication Date
9-1-2011
Publication Title
IEEE Electron Device Letters
Volume
32
Issue
9
Number of Pages
1200-1202
Document Type
Article
Personal Identifier
scopus
DOI Link
https://doi.org/10.1109/LED.2011.2160141
Copyright Status
Unknown
Socpus ID
80052038010 (Scopus)
Source API URL
https://api.elsevier.com/content/abstract/scopus_id/80052038010
STARS Citation
Malobabic, Slavica; Salcedo, Javier A.; Righter, Alan W.; Hajjar, Jean Jacques; and Liou, Juin J., "Correlation Of Human Metal Model And Transmission Line Pulsing Testing" (2011). Scopus Export 2010-2014. 2783.
https://stars.library.ucf.edu/scopus2010/2783