Title
Bayesian Methods For Time Course Microarray Analysis: From Genes’ Detection To Clustering
Keywords
Brackish water; Degasification; Desalination; Disinfection; Post-treatment; Seawater; Stabilization; Survey; Synthetic membrane processes
Abstract
As part of the Water Research Foundation (Denver, CO) project "Post-Treatment Stabilization of Desalinated Water," a questionnaire was developed and distributed to water utilities employing desalination processes to survey post-treatment practices, compile process and water quality data, highlight operating cost and post-treatment operation experiences, and identify distribution system secondary impacts. A total of eighty-three surveys were distributed to water utilities in the United States (USA), Caribbean and Europe, and responses collected over a period of six months duration from the time of initial mailing. Twenty-five questionnaires were returned yielding a thirty percent response rate. Twenty-one of the twenty-five responses were received from the USA, three from Europe and one response was received from the Caribbean. The average-daily permeate flow of the facilities surveyed ranged from 0.39 m3/min (0.15 million gallons per day (MGD)) to 184 m3/min (70 MGD). Results indicated a variety of methods are employed when post-treating desalinated permeate, with a majority of the surveyed facilities reporting the use of chemical addition using caustic soda (sodium hydroxide) or soda ash (sodium carbonate) for pH adjustment. More than one form of post-treatment was implemented with or without the need for by-pass or native source water blending, and was dependent on source water type. Facilities that relied upon process by-pass for post-treatment stabilization reported blending ratios between 10 and 30%, with an average blending flow rate between 5.26 m3/min (2.0 MGD) and 27.6 m3/min (10.5 MGD). Blended water alkalinity averaged 150 mg/l as CaCO3, as compared to post-treatment with alkalinity adjustment that approximated 62 mg/l as CaCO3 at the point-of-entry (POE). Primary disinfection was typically accomplished by chlorine addition, although a number of facilities reported using chloramines for secondary disinfection. The reported pH averaged 8.2 units at the POE. © 2012 Desalination Publications. All rights reserved.
Publication Date
1-1-2012
Publication Title
Advanced Statistical Methods for the Analysis of Large Data-Sets
Issue
1-3
Number of Pages
47-56
Document Type
Article; Book Chapter
Personal Identifier
scopus
DOI Link
https://doi.org/10.1007/978-3-642-21037-2_5
Copyright Status
Unknown
Socpus ID
85027321963 (Scopus)
Source API URL
https://api.elsevier.com/content/abstract/scopus_id/85027321963
STARS Citation
Angelini, Claudia; De Canditiis, Daniela; and Pensky, Marianna, "Bayesian Methods For Time Course Microarray Analysis: From Genes’ Detection To Clustering" (2012). Scopus Export 2010-2014. 4848.
https://stars.library.ucf.edu/scopus2010/4848