Title
Accuracy Of 3-Tesla Mr And Mr Arthrography In Diagnosis Of Meniscal Retear In The Post-Operative Knee
Keywords
Arthrography; Knee; MR
Abstract
Purpose: This study assesses the accuracy of 3-Tesla (3-T) conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography in the diagnosis of meniscal retears as compared with arthroscopy. The study also assess whether there are false-negative cases in which injected contrast does not extend into the meniscus despite a meniscal retear being seen on arthroscopy. Materials and methods: One hundred consecutive knee MR arthrograms performed on patients with previous knee surgery were reviewed retrospectively. 3-T conventional MR imaging, 3-T MR arthrography, and the combined use of conventional MR and MR arthrography were assessed for meniscal retears as compared with arthroscopy. The criterion used to diagnose a meniscal retear on MR arthrogram was injected contrast tracking into the meniscus. All patients underwent second-look arthroscopy. Results: Seventy-four patients had conventional MR findings consistent with a meniscal retear. In 83 of the 100 patients, intraarticular contrast helped in demonstrating a retear. In ten patients, there were MR findings consistent with a meniscal retear despite intra-articular contrast not tracking into the meniscus. Ninety-four of the 100 patients had meniscal retears on second-look arthroscopy. Three-Tesla conventional MR examination was 78 % sensitive and 75 % specific, MR arthrogram examination was 88 % sensitive and 100 % specific, and the combined use of MR and MR arthrogram imaging was 98 % sensitive and 75 % specific in the diagnosis of a meniscal retear. Conclusions: The combined use of 3-T MR and MR arthrography allows for high sensitivity and specificity in meniscal retear detection. In some patients, intraarticular contrast will not track into a meniscal retear. When MR findings are consistent with a meniscal retear but contrast does not extend into the meniscus, a meniscal retear is likely. © 2014 ISS.
Publication Date
1-1-2014
Publication Title
Skeletal Radiology
Volume
43
Issue
8
Number of Pages
1057-1064
Document Type
Review
Personal Identifier
scopus
DOI Link
https://doi.org/10.1007/s00256-014-1895-5
Copyright Status
Unknown
Socpus ID
84904059465 (Scopus)
Source API URL
https://api.elsevier.com/content/abstract/scopus_id/84904059465
STARS Citation
Magee, Thomas, "Accuracy Of 3-Tesla Mr And Mr Arthrography In Diagnosis Of Meniscal Retear In The Post-Operative Knee" (2014). Scopus Export 2010-2014. 9566.
https://stars.library.ucf.edu/scopus2010/9566