Experimental Study On The Waterstop With Adhesive Bonding
Keywords
Adhesive bonding; Waterproofing; Waterstop
Abstract
In this study, experimental investigation was carried out on the waterproofing performance of waterstop with and without adhesive bonding between concrete and waterstop. During underground structure construction, waterstop is typically used to prevent the water percolating through the joints where consecutive concrete casting is infeasible. For example, waterstop is often adopted at the joint between two panels of diaphragm walls. Conventional waterstop, however, often fails to prevent water percolation as the waterstop does not fully bond to the concrete, often making water passage through the gap between waterstop and concrete. Artificial adhesive bonding between the waterstop and the concrete was, therefore, applied to improve bonding and reduce water percolation. High water pressure was applied to the two waterstop waterproofing systems, one with adhesive and another without adhesive, and comparison was made between the two systems.
Publication Date
1-1-2018
Publication Title
11th International Conference on Geosynthetics 2018, ICG 2018
Volume
1
Number of Pages
576-580
Document Type
Article; Proceedings Paper
Personal Identifier
scopus
Copyright Status
Unknown
Socpus ID
85099663659 (Scopus)
Source API URL
https://api.elsevier.com/content/abstract/scopus_id/85099663659
STARS Citation
Cho, Byoung Hooi; Nam, Boo Hyun; Seo, Sangyeon; Kim, Jungil; and Youn, Heejung, "Experimental Study On The Waterstop With Adhesive Bonding" (2018). Scopus Export 2015-2019. 10141.
https://stars.library.ucf.edu/scopus2015/10141