The Effect Of A Head-Mounted Low Vision Device On Visual Function

Abstract

SIGNIFICANCE Head-mounted low vision devices have received considerable attention in recent years owing to rapidly developing technology, facilitating ease of use and functionality. Systematic clinical evaluations of such devices remain rare but are needed to steer future device development. PURPOSE The purpose of this study was to investigate, in a multicenter prospective trial, the short-A nd medium-term effects of a head-worn vision enhancement device (eSight Eyewear). METHODS Participants aged 13 to 75 years with stable vision (distance acuity, 20/60 to 20/400; visual field diameter >20°) were recruited across six sites. Data were collected at baseline (no device), at fitting (with device), and after 3 months of everyday use. Outcome measures were visual ability measured by the Veterans Affairs Low Vision Visual Functioning Questionnaire 48, distance acuity (Early Treatment Diabetic Retinopathy Study), reading performance (MNREAD chart), contrast sensitivity (MARS chart), face recognition, and a modified version of the Melbourne Low Vision Activities of Daily Living (ADL) Index. RESULTS Among the 51 participants, eSight introduction immediately improved distance acuity (0.74 ± 0.28 logMAR), contrast sensitivity (0.57 ± 0.53 log units), and critical print size (0.52 ± 0.43 logMAR), all P <.001, without any further change after 3 months; reading acuity improved at fitting (0.56 ± 0.35 logMAR) and by one additional line after 3 months, whereas reading speed only slightly increased across all three time points. The Melbourne ADL score and face recognition improved at fitting (P <.01) with trends toward further improvement at 3 months. After 3 months of use, Veterans Affairs Low Vision Visual Functioning Questionnaire 48 person measures (in logits) improved: Overall, 0.84, P <.001; reading, 2.75, P <.001; mobility, 0.04, not statistically significant; visual information, 1.08, P <.001; and visual motor, 0.48, P =.02. CONCLUSIONS eSight introduction yields immediate improvements in visual ability, with face recognition and ADLs showing a tentative benefit of further use. Overall, visual ability, reading, and visual information showed greatest benefit with device use. Further studies need to examine benefits of practice and training and possible differential effects of underlying pathology or baseline vision.

Publication Date

9-1-2018

Publication Title

Optometry and Vision Science

Volume

95

Issue

9

Number of Pages

774-784

Document Type

Article

Personal Identifier

scopus

DOI Link

https://doi.org/10.1097/OPX.0000000000001262

Socpus ID

85052717768 (Scopus)

Source API URL

https://api.elsevier.com/content/abstract/scopus_id/85052717768

This document is currently not available here.

Share

COinS