Performance Characteristics Of Cerebrospinal Fluid Cytology: An Analysis Of Responses From The College Of American Pathologists Nongynecologic Cytopathology Education Program
Abstract
Context.-Cerebrospinal fluid cytology is a critical diagnostic tool for the diagnosis of many conditions affecting the central nervous system. Objective.-To assess the performance characteristics of cerebrospinal fluid cytology samples by evaluating participant interpretations within the College of American Pathologists Nongynecologic Cytopathology Education program. Design.-Participant interpretations (N 1/4 46 264) evaluated in the College of American Pathologists Nongynecologic Cytopathology Education Program were examined for concordance with the general category and with the reference diagnosis. Two nonlinear mixed models were used to analyze the concordance rates. Results.-The overall concordance rates for the general category and reference diagnosis were 92.1% and 81.0%, respectively. In the malignant category, the concordance rates with the reference diagnosis were lowest for diagnoses of nonhematopoietic small blue round cell tumors (54.8%) and metastatic malignancy (77.5%); the concordance rate with the reference diagnosis was highest for leukemia/ lymphoma (94.0%). In the benign category, the concordance rate was lowest for normal cerebrospinal fluid reference diagnoses (58.6%), followed by acute and chronic inflammation (64.6%), fungal infection (80.8%), and macrophages (85.3%). Significant differences in concordance were uncovered when performance was evaluated by participant type and stain technique. Leukemia/lymphoma was the most common diagnosis for misclassified nonhematopoietic small blue round cell tumor cases and negative or inflammatory cerebrospinal fluid cases. Conclusions.-This study illustrates the difficulties in achieving accurate diagnoses from cerebrospinal fluid specimens, particularly for nonhematopoietic small blue round cell tumors and normal and inflammatory cerebrospinal fluid specimens.
Publication Date
7-1-2018
Publication Title
Archives of Pathology and Laboratory Medicine
Volume
142
Issue
7
Number of Pages
833-837
Document Type
Article
Personal Identifier
scopus
DOI Link
https://doi.org/10.5858/arpa.2017-0167-CP
Copyright Status
Unknown
Socpus ID
85049149688 (Scopus)
Source API URL
https://api.elsevier.com/content/abstract/scopus_id/85049149688
STARS Citation
Tabatabai, Z. Laura; Auger, Manon; Souers, Rhona J.; Teot, Lisa; and Davey, Diane D., "Performance Characteristics Of Cerebrospinal Fluid Cytology: An Analysis Of Responses From The College Of American Pathologists Nongynecologic Cytopathology Education Program" (2018). Scopus Export 2015-2019. 10359.
https://stars.library.ucf.edu/scopus2015/10359