Pre-concentration of water samples with BEA zeolite for the direct determination of polycyclic aromatic hydrocarbons with laser-excited time-resolved Shpol'skii spectroscopy

Authors

    Authors

    W. B. Wilson; A. A. Costa; H. Y. Wang; A. D. Campiglia; J. A. Dias;S. C. L. Dias

    Comments

    Authors: contact us about adding a copy of your work at STARS@ucf.edu

    Abbreviated Journal Title

    Microchem J.

    Keywords

    Zeolites; BEA; Polycyclic aromatic hydrocarbons; Solid-phase extraction; Laser-excited time-resolved Shpol'skii spectroscopy; Shpol'skii; spectroscopy; Water analysis; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; MOLECULAR-WEIGHT 302; MULTIDIMENSIONAL FLUORESCENCE SPECTROSCOPY; 15; PRIORITY POLLUTANTS; DRINKING-WATER; LUMINESCENCE SPECTROSCOPY; DIBENZOPYRENE ISOMERS; NANO-EXTRACTION; FACILE METHOD; Chemistry, Analytical

    Abstract

    A unique method for screening fifteen US Environmental Protection Agency polycyclic aromatic hydrocarbons (EPA-PAHs) in drinking and lake water samples is reported. One milliliter volume of water sample is mixed and centrifuged with 2 mg of BEA zeolite. The precipitate is subsequently treated with equal volumes (100 mu L) of a 70/30 methanol-water mixture and n-octane. Fifteen EPA-PAHs are directly determined (no chromatographic separation) in the layer of n-octane via 4.2 K laser-excited time-resolved Shpol'skii spectroscopy. A mathematical equation is derived to correlate the PAH concentration in the water sample to its concentration in the layer of Shpol'skii solvent (n-octane). Qualitative and quantitative analyses are based on the collection of wavelength-time matrices, i.e. data formats that carry with them spectral and lifetime information. With 1 mL of water, the limits of detection varied from 1.1 ng L-1 (benzo[a]pyrene) to 194 ng L-1 (naphthalene). The analytical recoveries of the new method are in good agreement with those obtained via high-performance liquid chromatography. The simplicity of the experimental procedure and the use of microliters of organic solvent make the new method a valuable and environmentally friendly alternative for the routine monitoring of EPA-PAHs in water samples. (C) 2013 Elsevier B.V. All rights reserved.

    Journal Title

    Microchemical Journal

    Volume

    110

    Publication Date

    1-1-2013

    Document Type

    Article

    Language

    English

    First Page

    246

    Last Page

    255

    WOS Identifier

    WOS:000326851200036

    ISSN

    0026-265X

    Share

    COinS