Keywords

Shock tubes, Shock waves

Abstract

Previous tests of an explosion driven hydrodynamic shock tube revealed peak pressure data significantly lower than values predicted from the semiempirical scaling laws. It was hypothesized that part of the deviation was due to error in determining shock wave parameters and part might be due to measurement error caused by mechanical vibration of the tube. This investigation was conducted in two parts. In the first part, shock wave parameters were determined using a digital computer and curve fitting techniques to analyze digitized shock wave data. The second part involved determining the frequency components of the shock wave data noise content and comparing this to the dynamic characteristics of the tube which were investigated through an impulse testing technique. From these efforts higher values for the peak pressure were verified but no evidence was found that vibration of the tube caused significant degradation of shock wave test data.

Notes

If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at STARS@ucf.edu

Graduation Date

Summer 1981

Advisor

Nuckolls, Charles E.

Degree

Master of Science (M.S.)

College

College of Engineering

Degree Program

Engineering

Format

PDF

Pages

161 p.

Language

English

Rights

Public Domain

Length of Campus-only Access

None

Access Status

Masters Thesis (Open Access)

Identifier

DP0013585

Accessibility Status

Searchable text

Included in

Engineering Commons

Share

COinS